CHIPDRIVE CLOUD 4700F 905511 数据表

产品代码
905511
下载
页码 98
CLOUD
 
47
X
0
 
F
 
R
EFERENCE 
M
ANUAL
  
80 
 
Output: 
For retrieving all settings (0xFE), the output will be: 
 
For retrieving current Power up sequence (0xFF), the output will be: 
 
 
 
 
 
 
 
6.3.5.2. CONTACT_EMV_LOOPBACK 
 
This Escape command lets the host force the firmware to perform an EMV Loop-back 
application. 
 
Input: 
The input buffer contains the escape code value.  
 
 
 
Output
Output buffer 
NULL 
 
Byte0 
Byte 1 
Byte2 
Value  Description 
 
0x00 
Starts with Class C voltage.  
(1.8V – 3V – 5V order) 
Time delay between 
resets in milliseconds 
Bit Map of all Voltage 
Classes  
[Bit0  –  Class A; Bit1 – 
Class B; Bit2 – Class C] 
 
 
0x01 
Starts with Class A voltage. 
(5V – 3V – 1.8V order) 
Byte0 
Value  Description 
 
0x00 
Starts with Class C voltage.  (1.8V – 3V – 5V order) 
 
0x01 
Starts with Class A voltage. (5V – 3V – 1.8V order) 
Byte0 
Escape code(0x05)