- Inspect output cable without exposing the metal to ensure insulation.
- Do not operate the adapter around explosive gas, vapor or dust.
- Do not exceed the rated voltage/current as marked on the adapter.
- Use with extreme caution when working around bare conductors or bus bars. It could
results in electric shock if have accidentally contact to the conductors.
- Always keep your hand behind the fi nger guard of clamp jaw.
- When servicing the adapter, use only specifi ed replacement parts.
- Use with caution when working above 30 V ac rms, 42 V peak or 60 V dc. Such
voltage poses a shock hazard.
- Avoid working alone.
- Do not operate the adapter if the cover is removed or loosened.
- Do not connect to BNC output or banana plug to any power sources.
- Use the proper terminals, function, and range for your measurements.
Standard Item Purchased Checklist
The following items are included when you make a purchase:
•
U1583B current clamp
• BNC-to-banana
plug
•
Operating Instructions sheet (this sheet)
General Specifi cations
Specifi cations
Current Clamp
Specifi cations
Current Clamp
Specifi ed Current Range
1 A to 400 A ac
Load impedance
> 1 M ohm, < 100 pF
Usable Current Range
0.5 A to 400 A
Operating Temperature
–10 °C to 55 °C (14 °F to 131 °F)
AC crest factor
< 3
Storage Temperature
–20 °C to 70 °C (–4 °F to 158 °F)
Bandwidth
10 kHz
Measurement Category
CAT III 600 V; Pollution degree II
Weight
294 grams
Dimensions (HxWxD)
44 mm (H) x 92 mm (W) x 188 mm (L)
Cable length
1500 +/– 20 mm
Maximum conductor size
30 mm or 16 mm x 2
Maximum Jaw Opening
32 mm
Warm-up time
Immediately upon power on
Altitude
Up to 2000 meters
Warranty
One year
Relative Humidity
Max 80% RH for temperature up to 35 °C decreasing linearly to 50% RH at 55 °C
Safety Compliance
Safety Compliance Certifi ed by CSA (Canada & USA) for IEC/EN/UL 61010-1 2nd Edition &
EN/IEC 61010-2-032
EMC Compliance
Certifi ed to IEC/EN 61326:2002, CISPR 11, and equivalents for Group 1, Class A
Electrical Accuracy Specifi cations
Range
Output
Resolution
Accuracy
± (% of reading + digit) at 23 °C ±5 °C, with relative humidity less than 80% R.H.
Span
48 Hz ~ 65 Hz
40 ~ 48 Hz/
65 Hz ~ 1 kHz
1 kHz ~ 10 kHz
40 A
10 mV/A
0.5 A ~ 40 A
2 % + 0.5 A
5 % + 0.5 A
10 % + 0.5 A
400 A
1 mV/A
0.5 A ~ 40 A
2.5 % + 0.5 A
4.5 % + 0.5 A
12.5 % + 0.5 A
40 A ~ 200 A
2 % + 0.5 A
4 % + 0.5 A
12 % + 0.5 A
200 A ~ 400 A
1.5 % + 0.5 A
3.5 % + 0.5 A
11.5 % + 0.5 A
• The current conductor must be centered within the jaw aperture and no infl uence from adjacent
currents.
• Connect to load impedance > 1 MW ||100 pF.
• Crest factor < 3.