Leica Geosystems Jogger20 Automatic Level 762263 Benutzerhandbuch

Produktcode
762263
Seite von 82
4
Checking and adjusting of the 
line-of-sight
Jogger 20/24/28/32-1.1.0en
EN
DE
FR
ES
PT
IT
NO
4. Checking and adjusting of the line-of-sight
With the circular bubble centred 
and adjusted, the line of sight 
should be horizontal.
Checking (see example):
1. Choose a distance of appr. 30 m 
within a gentle terrain.
2. Set up a staff at both final points 
(A, B).
3. Set up the instrument at point I
1
 
(halfway between A and B, just 
pass it down) and centre the 
bubble.
4. Read both staffs.
reading on A = 1.832 m
reading on B = 1.616 m
Δ
H = A - B = 0.216 m
5. Set up the level about 1 m from 
staff A
6. Read staff A (eg.: 1.604 m)
7. Find nominal reading B; eg.: 
Reading A - 
Δ
H = 1.604 m - 
0.216 m = 1.388 m
8. Read staff B, compare nominal-
/actual- reading.
)
When the difference 
nominal-/actual- reading is more 
than 3 mm the line of sight must be 
adjusted.
1. Turn the adjusting srew until the 
middle hair gives the required 
reading (eg. 1.388 m).
2. Check line of sight again.
)
Before starting field work 
or after long periods of storage/
transport of your equipment check 
the field adjustment parameters 
specified in this User Manual.
d
d
A
B
Δ
H
H=1.832
H=1.616
δ
δ
I
1
A
B
Δ
H
δ
I
2
actual = 1.604
nominal
= 1.388