Texas Instruments LM3423 Evaluation Board LM3423BBLSCSEV/NOPB LM3423BBLSCSEV/NOPB Datenbogen

Produktcode
LM3423BBLSCSEV/NOPB
Seite von 67
SNVS574E – JULY 2008 – REVISED MAY 2013
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1) (2)
V
IN
, EN, RPD, nDIM
-0.3V to 76.0V
-1 mA continuous
OVP, HSP, HSN, LRDY, FLT, DPOL
-0.3V to 76.0V
-100 µA continuous
RCT
-0.3V to 76.0V
-1 mA to +5 mA continuous
IS
-0.3V to 76.0V
-2V for 100 ns
-1mA continuous
V
CC
-0.3V to 8.0V
TIMR
-0.3V to 7.0V
-100µA to +100µA Continuous
COMP, CSH
-0.3V to 6.0V
-200 µA to +200 µA Continuous
GATE, DDRV
-0.3V to V
CC
-2.5V for 100 ns
V
CC
+2.5V for 100 ns
-1 mA to +1 mA continuous
PGND
-0.3V to 0.3V
-2.5V to 2.5V for 100 ns
Maximum Junction Temperature
Internally Limited
Storage Temperature Range
65°C to +150°C
Maximum Lead Temperature (Solder and Reflow)
(3)
260°C
Continuous Power Dissipation
Internally Limited
ESD Susceptibility
(4)
Human Body Model
2 kV
Charge Device Model
500V CSH pin
750V all other pins
(1)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Operating Ratings is not implied. The recommended Operating Ratings indicate
conditions at which the device is functional and the device should not be operated beyond such conditions. All voltages are with respect
to the potential at the AGND pin, unless otherwise specified.
(2)
If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/Distributors for availability and
specifications.
(3)
Refer to
for more detailed information and mounting techniques.
(4)
The human body model is a 100 pF capacitor discharged through a 1.5 k
Ω
resistor into each pin. The applicable standard is JESD22-
A114C.
Operating Conditions
(1)
Operating Junction Temperature Range
LM3421, LM3421Q1,
LM3423, LM3423Q1
40°C to +125°C
LM3421Q0, LM3423Q0
40°C to +150°C
Input Voltage V
IN
4.5V to 75V
(1)
Absolute Maximum Ratings indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Operating Ratings is not implied. The recommended Operating Ratings indicate
conditions at which the device is functional and the device should not be operated beyond such conditions. All voltages are with respect
to the potential at the AGND pin, unless otherwise specified.
4
Copyright © 2008–2013, Texas Instruments Incorporated
Product Folder Links: