4.4
ACCESS MODES
The bq27505 provides three security modes (FULL ACCESS, UNSEALED, and SEALED) that control
data flash access permissions, according to
Data Flash refers to those data flash locations,
specified in
, that are accessible to the user. Manufacture Information refers to the three 32-byte
blocks.
Table 4-6. Data Flash Access
Security Mode
Data Flash
Manufacture Information
FULL ACCESS
R/W
R/W
UNSEALED
R/W
R/W
SEALED
None
R(A); R/W(B)
Although FULL ACCESS and UNSEALED modes appear identical, only FULL ACCESS allows the
bq27505 to write access-mode transition keys.
4.5
SEALING/UNSEALING DATA FLASH
The bq27505 implements a key-access scheme to transition between SEALED, UNSEALED, and
FULL-ACCESS modes. Each transition requires that a unique set of two keys be sent to the bq27505 via
the Control( ) control command. The keys must be sent consecutively, with no other data being written to
the Control( ) register in between. Note that to avoid conflict, the keys must be different from the codes
presented in the CNTL DATA column of
subcommands.
When in SEALED mode, the CONTROL_STATUS [SS] bit is set, but when the UNSEAL keys are
correctly received by the bq27505, the [SS] bit is cleared. When the full-access keys are correctly
received, then the CONTROL_STATUS [FAS] bit is cleared.
Both the sets of keys for each level are 2 bytes each in length and are stored in data flash. The UNSEAL
key (stored at Unseal Key 0 and Unseal Key 1) and the FULL-ACCESS key (stored at Full-Access Key
and Full-Access Key 1) can only be updated when in FULL-ACCESS mode. The order of the keys is
Key 1 followed by Key 0. The order of the bytes entered through the Control( ) command is the reverse of
what is read from the part. For example, if the Key 1 and Key 0 of the Unseal Keys returns 0x1234 and
0x5678, then the Control( ) should supply 0x3412 and 0x7856 to unseal the part.
4.6
DATA FLASH SUMMARY
summarizes the data flash locations available to the user, including their default, minimum, and
maximum values.
Table 4-7. Data Flash Summary
Subclass
Data
Min
Max
Default
Class
Subclass
Offset
Name
Units
ID
Type
Value
Value
Value
Configuration
2
Safety
0
OT Chg
I2
0
1200
550
0.1°C
Configuration
2
Safety
2
OT Chg Time
U1
0
60
2
s
Configuration
2
Safety
3
OT Chg Recovery
I2
0
1200
500
0.1°C
Configuration
2
Safety
5
OT Dsg
I2
0
1200
600
0.1°C
Configuration
2
Safety
7
OT Dsg Time
U1
0
60
2
s
Configuration
2
Safety
8
OT Dsg Recovery
I2
0
1200
550
0.1°C
Charge Inhibit
Configuration
32
0
Charge Inhibit Temp Low
I2
–400
1200
0
0.1°C
Temp Low
Charge Inhibit
Configuration
32
2
Charge Inhibit Temp High
I2
–400
1200
450
0.1°C
Temp High
Temp
Configuration
32
4
Temp Hys
I2
0
100
50
0.1°C
Hysteresis
Configuration
34
Charge
2
Charging Voltage
I2
0
4600
4200
mV
Configuration
34
Charge
4
Delta Temp
I2
0
500
50
0.1°C
Copyright © 2009, Texas Instruments Incorporated
GENERAL DESCRIPTION
21
Product Folder Link(s):