Table 4-7. Data Flash Summary (continued)
Subclass
Data
Min
Max
Default
Class
Subclass
Offset
Name
Units
ID
Type
Value
Value
Value
Current
Gas Gauging
81
4
Quit Current
I2
0
1000
40
mA
Thresholds
Current
Gas Gauging
81
6
Dsg Relax Time
U2
0
8191
60
s
Thresholds
Current
Gas Gauging
81
8
Chg Relax Time
U1
0
255
60
s
Thresholds
Current
Gas Gauging
81
9
Quit Relax Time
U1
0
63
1
s
Thresholds
Gas Gauging
82
State
0
IT Enable
H1
0x00
0x03
0x00
Gas Gauging
82
State
1
Application Status
H1
0x00
0xff
0x00
Gas Gauging
82
State
2
Qmax 0
I2
0
32,767
1000
mAh
Gas Gauging
82
State
4
Cycle Count 0
U2
0
65,535
0
Gas Gauging
82
State
6
Update Status 0
H1
0x00
0x03
0x00
Gas Gauging
82
State
7
Qmax 1
I2
0
32767
1000
mAh
Gas Gauging
82
State
9
Cycle Count 1
U2
0
65,535
0
Count
Gas Gauging
82
State
11
Update Status 1
H1
0x00
0x03
0x00
Gas Gauging
82
State
12
Cell0 Chg dod
I2
0
16384
0
Gas Gauging
82
State
14
Cell1 Chg dod at EoC
I2
0
16384
0
Gas Gauging
82
State
16
Avg I Last Run
I2
–32,768
32,767
–299
mA
Gas Gauging
82
State
18
Avg P Last Run
I2
–32,768
32,767
–1131
mAh
Calibration
104
Data
0
CC Gain
F4
(2)
0.1
47
10
(3)
mohm
Calibration
104
Data
4
CC Delta
F4
(2)
4.7
188
10
(3)
mohm
Calibration
104
Data
8
CC Offset
I2
–2.4
2.4
–0.088
(3)
mV
Calibration
104
Data
10
ADC Offset
I2
–500
500
0
mV
Calibration
104
Data
12
Board Offset
I1
–128
127
0
mV
Calibration
104
Data
13
Int Temp Offset
I1
–128
127
0
0.1°C
Calibration
104
Data
14
Ext Temp Offset
I1
–128
127
0
0.1°C
Calibration
104
Data
15
Pack V Offset
I1
–128
127
0
mV
Calibration
107
Current
1
Deadband
U1
0
255
5
mA
Security
112
Codes
0
Unseal Key 0
H2
0x0000
0xffff
0x3672
Security
112
Codes
2
Unseal Key 1
H2
0x0000
0xffff
0x0414
Security
112
Codes
4
Full-Access Key 0
H2
0x0000
0xffff
0xffff
Security
112
Codes
6
Full-Access Key 1
H2
0x0000
0xffff
0xffff
(2)
Not IEEE floating point.
(3)
Display as the value EVSW displayed. Data Flash value is different.
5
FUNCTIONAL DESCRIPTION
5.1
FUEL GAUGING
The bq27505 measures the cell voltage, temperature, and current to determine battery SOC. The
bq27505 monitors charge and discharge activity by sensing the voltage across a small-value resistor
(5 m
Ω
to 20 m
Ω
typ.) between the SRP and SRN pins and in series with the cell. By integrating charge
passing through the battery, the battery’s SOC is adjusted during battery charge or discharge.
The total battery capacity is found by comparing states of charge before and after applying the load with
the amount of charge passed. When an application load is applied, the impedance of the cell is measured
by comparing the OCV obtained from a predefined function for present SOC with the measured voltage
under load. Measurements of OCV and charge integration determine chemical state of charge and
chemical capacity (Qmax). The initial Qmax values are taken from a cell manufacturers' data sheet
multiplied by the number of parallel cells. It is also used for the value in Design Capacity. The bq27505
acquires and updates the battery-impedance profile during normal battery usage. It uses this profile, along
Copyright © 2009, Texas Instruments Incorporated
FUNCTIONAL DESCRIPTION
23