Texas Instruments Evaluation Module for TLV70433 TLV70433DBVEVM-712 TLV70433DBVEVM-712 Datenbogen

Produktcode
TLV70433DBVEVM-712
Seite von 11
Setup
www.ti.com
2
Setup
This section describes the connectors and ground connections found on the EVM as well as how to
properly connect, set up, and use the TLV70433DBVEVM-712 or TLV70433PKEVM-712.
2.1
Input / Output Connectors, Jumper, and Resistor Descriptions
J4: VIN
The positive input lead and ground return lead from the input power supply should be twisted and kept
as short as possible to minimize electromagnetic interference (EMI) transmission. Additional bulk
capacitance should be added between J4 and J2 (GND) if the supply leads are greater than 6 in
(15.24 cm) in length. For example, an additional leaded 47-
m
F electrolytic capacitor connected from J4
to J2 (GND) improves the transient response of the TLV70728 by eliminating unwanted ringing that
sometimes occurs as a result of long wire connections.
J2: GND
This is the ground-return connection for the input power supply.
J5: VOUT
This is the regulated output voltage connector.
J1: GND
This is the output ground-return connector.
J3
This test jack/jumper is used to do one of the folllowing:
Measure the LDO ground or quiescent current; or
When connected by a shorting strip (not provided with the EVM), to provide an alternative means to
ground either of the LDO packages when R
1
or R
2
is not installed.
R1 and R2
0-
Ω
resistors that connect the ground pin of either respective LDO package (SOT89 or SOT23) to the
ground plane. If this resistor is removed, then this ground connection must be made across the J3 test
jack/jumper using a shorting strip (not provided with the EVM).
2.2
Soldering Guidelines
Any solder re-work to modify the EVM for the purpose of repair or other application reasons must be
performed using a hot-air system to avoid damaging the integrated circuit (IC).
2.3
Equipment Setup
Follow these procedures to set up the test equipment properly.
Turn off the input power supply after verifying that its output voltage is set to less than 24 V. Connect
the positive voltage lead from (+) the input power supply to V
IN
, at the J4 connector of the EVM.
Connect the ground lead from the (–) input power supply to GND at the J2 connector of the EVM.
Connect a 0-mA to 150-mA load between the output (V
OUT
) at connector J5 and ground at connector
J1.
3
Operation
Follow these procedures to correctly operate the TLV70433DBVEVM-712 or TLV70433PKEVM-712.
Turn on the input power supply. For initial operation, it is recommended that the input power supply,
V
IN
– J4, be set between 5 V and 10 V.
Vary the respective loads and V
IN
voltages as necessary for test purposes.
2
TLV70433DBVEVM-712, TLV70433PKEVM-712 Evaluation Modules
SBVU017 – January 2011
© 2011, Texas Instruments Incorporated