Texas Instruments Evaluation Module for BQ24172 1.6-MHz Synchronous Switch-Mode Li-Ion and Li-Polymer Battery Charger BQ BQ24172EVM-706-15V Datenbogen

Produktcode
BQ24172EVM-706-15V
Seite von 20
Bq24171 EVM
BQ24172 EVM
HPA706
VIN
J1
PGND
VSYS
J2
PGND
VBAT
APPLICATION CIRCUIT
TP2
SW
U1
V
Iin
I
Power supply
#1
Iout
V
Isys
V
I
Load #1
Load #2
I
TS_EXT
/STAT
JP2
TEST POINTS
D1
JP3
JP4
CE
TTC
LED
SETTINGS
JP1
LEDPWR
Test Summary
www.ti.com
2.5.2
Loads
LOAD#1 A 30-V (or greater), 5-A (or greater) electronic load that can operate at constant current and
constant voltage mode.
LOAD#2: An HP 6060B 3-V to 60-V/0-A to 60-A, 300-W system dc electronic load or equivalent.
2.5.3
Meters
Seven Fluke 75 multimeters (equivalent or better) or four equivalent voltage meters and three equivalent
current meters.
The current meters must be capable of measuring 5-A+ current.
2.6
Equipment Setup
1. Set the power supply #1 (PS#1) for 6-V ±200-mVdc (001), or 16-V ±0.200-mVdc (002 / 003),4.5-A
±0.1-A current limit, and then turn off supply.
2. Connect the output of PS#1 in series with a current meter (multimeter) to J1 (VIN, PGND).
3. Connect a voltage meter across J1 (VIN, PGND).
4. Connect Load#1 in series with a current meter to J2 (VBAT, PGND). Turn off Load#1.
5. Connect Load#2 in series with a current meter to J2 (VSYS, PGND). Turn off Load#2.
6. Connect a voltage meter across J2 (VBAT, PGND).
7. Connect a voltage meter across J2 (VSYS, PGND).
8. Check all jumper shunts. JP1: connect 2-3 (External TS); JP2: ON; JP3: OPEN; JP4: OPEN.
Figure 1. Original Test Setup for HPA706 Evaluation Board ( bq24171EVM and bq24712EVM)
6
bq24171EVM JEITA Compliant and bq24172EVM Stand-Alone Synchronous, SLUU462A – November 2010 – Revised February 2011
Switch-Mode, Battery-Charge With Integrated N-MOSFETs and Power Path
Selector
© 2010–2011, Texas Instruments Incorporated