Texas Instruments EVM430-F6736 - MSP430F6736 EVM for Metering EVM430-F6736 EVM430-F6736 Datenbogen

Produktcode
EVM430-F6736
Seite von 124
MSP430F673x
MSP430F672x
SLAS731C – DECEMBER 2011 – REVISED FEBRUARY 2013
Outputs – General Purpose I/O (Reduced Drive Strength)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
(1)
PARAMETER
TEST CONDITIONS
V
CC
MIN
MAX
UNIT
I
(OHmax)
= –1 mA
(2)
V
CC
– 0.25
V
CC
1.8 V
I
(OHmax)
= –3 mA
(2)
V
CC
– 0.60
V
CC
V
OH
High-level output voltage
V
I
(OHmax)
= –2 mA
(2)
V
CC
– 0.25
V
CC
3.0 V
I
(OHmax)
= –6 mA
(2)
V
CC
– 0.60
V
CC
I
(OLmax)
= 1 mA
(3)
V
SS
V
SS
+ 0.25
1.8 V
I
(OLmax)
= 3 mA
(4)
V
SS
V
SS
+ 0.60
V
OL
Low-level output voltage
V
I
(OLmax)
= 2 mA
(3)
V
SS
V
SS
+ 0.25
3.0 V
I
(OLmax)
= 6 mA
(4)
V
SS
V
SS
+ 0.60
(1)
Selecting reduced drive strength may reduce EMI.
(2)
The maximum total current, I
(OHmax)
, for all outputs combined should not exceed ±20 mA to hold the maximum voltage drop specified.
See
for more details.
(3)
The maximum total current, I
(OLmax)
, for all outputs combined, should not exceed ±48 mA to hold the maximum voltage drop specified.
(4)
The maximum total current, I
(OLmax)
, for all outputs combined, should not exceed ±100 mA to hold the maximum voltage drop specified.
Copyright © 2011–2013, Texas Instruments Incorporated