Texas Instruments RM46 Hercules Safety MCU controlCARD TMDXRM46CNCD TMDXRM46CNCD Datenbogen

Produktcode
TMDXRM46CNCD
Seite von 183
SPNS184A – SEPTEMBER 2012 – REVISED SEPTEMBER 2013
3.6
Input/Output Electrical Characteristics Over Recommended Operating Conditions
(1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
V
hys
Input hysteresis
All inputs
180
mV
V
IL
Low-level input voltage
All inputs
-0.3
0.8
V
V
IH
High-level input voltage
All inputs
2
V
CCIO
+ 0.3
V
I
OL
= I
OLmax
0.2 V
CCIO
I
OL
= 50 µA, standard
0.2
output mode
V
OL
Low-level output voltage
V
I
OL
= 50 µA, low-EMI
0.2 V
CCIO
output mode (see
I
OH
= I
OHmax
0.8 V
CCIO
I
OH
= 50 µA, standard
V
CCIO
-0.3
output mode
V
OH
High-level output voltage
V
I
OH
= 50 µA, low-EMI
0.8 V
CCIO
output mode (see
V
I
< V
SSIO
- 0.3 or V
I
-3.5
3.5
I
IC
Input clamp current (I/O pins)
mA
> V
CCIO
+ 0.3
I
IH
Pulldown 20µA
V
I
= V
CCIO
5
40
I
IH
Pulldown 100µA
V
I
= V
CCIO
40
195
I
I
Input current (I/O pins)
I
IL
Pullup 20µA
V
I
= V
SS
-40
-5
µA
I
IL
Pullup 100µA
V
I
= V
SS
-195
-40
All other pins
No pullup or pulldown
-1
1
C
I
Input capacitance
2
pF
C
O
Output capacitance
3
pF
(1)
Source currents (out of the device) are negative while sink currents (into the device) are positive.
52
Device Operating Conditions
Copyright © 2012–2013, Texas Instruments Incorporated
Product Folder Links: