Basic Test Procedure
Figure 3. Test Setup Block Diagram
3.2
Test Setup Connection
1. Connect DAC328x EVM to TSW3100 EVM
2. Connect 6-V power-supply jack
3. Connect RF output to Spectrum Analyzer
4. Connect USB cable to programming computer
3.3
TSW3100 Quick-Start Operation
See the TSW3100 User’s Guide for more detailed explanations of the TSW3100 setup and operation. This
document assumes the TSW3100 software is installed and functioning properly. The DAC328x uses
byte-wide DDR operation; hence, TSW3100 operating software version 2.2 or later is required. Also, the
DAC328x can operate at higher data rates, so verify that the oscillator on the TSW3100 at Y3 is operating
at 125 MHz to support the data rates above 250 MHz. The front panel of the TSW3100 is shown in
and
. The following registers must be changed from the default settings.
Multitone Setup From Default Configuration
1. Change sample rate to equal DAC clock rate / Interpolation (i.e., 614.4 / 2 = 307.2).
2. Select desired tone groups (i.e., group 1: tone center = 20, group 2: tone center = 21)
3. Select BwDDR output button
4. Check the LOAD and Run box
5. Press the
green
Create and Save/Run TSW3100 button
CommsSignalPattern Setup From Default Configuration (WCDMA)
1. Change Interpolation value to (DAC clock rate / Interpolation) / 3.84 [i.e., (614.4 / 2) / 3.84 = 80]
2. Enter desired offset frequency (i.e., 30 MHz) for each desired carrier
3. Select the BwDDR output button
4. Check the LOAD and Run box
5. Press the
green
Create button
5
SLAU304C – February 2010 – Revised November 2010
DAC3282
Copyright © 2010, Texas Instruments Incorporated