Setup and Operation
JP2 - PS:
This jumper enables or disables the power save mode at light load. Place a shunt across
the VBAT and PS pins of JP2 to disable power save mode. Place a shunt across the GND
and PS pins of JP2 to enable power save mode. Note that while operating in down
conversion mode (VBAT > Vout), power save mode is always enabled and the device
cannot be forced into fixed frequency operation. A shunt must be installed on JP2 in either
VBAT or GND positions and PS should not be left unconnected.
The power supply should have at least 2A capability. Connect an input power supply between J1 and J2.
Initially the voltage range on this supply to start up the converter should be between 0.5V and 5.5V due to
the minimum start up voltage requirement. Following startup, the input can be as low as 0.3V. Connect the
load between J3 and J4.
Before enabling this device by connecting the EN pin to VBAT at JP1, make sure the measured input
voltage between J1 and J2 does not exceed 5.5V and JP2 (PS pin) is connected to the desired setting.
In order to avoid voltage drop through the input power supply line, use at least 20 gauge wire. The output
voltages can be monitored by voltmeters and/or an oscilloscope with standard high impedance voltage
probes.
Once the input voltage is connected and verified, connect the EN pin to VBAT at JP1. The converter starts
up and regulates to the set output voltage. The range for the output regulation is shown in
After the converter starts up, the input voltage can go down to 0.3V.
and
show
measured data from the EVM for maximum output current and efficiency at various input/output voltage
combinations.