Texas Instruments Clock Jitter Cleaner With Dual Cascaded PLLs and Integrated 2.5 GHz VCO LMK04806BEVAL/NOPB LMK04806BEVAL/NOPB Datenbogen

Produktcode
LMK04806BEVAL/NOPB
Seite von 78
 
L M K 0 4 8 X X   E V A L U A T I O N   B O A R D   O P E R A T I N G   I N S T R U C T I O N S  
 
 
 
 
 
31 
PLL2 Tab 
 
Figure 12: PLL2 tab 
 
The PLL2 tab allows the user to change the following parameters in Table 9. 
 
Table 9: Registers Controls and Descriptions in PLL2 tab 
Control Name 
Register Name 
Description  
Reference Oscillator 
Frequency (MHz) 
OSCin_FREQ 
OSCin frequency from the External VCXO 
or Crystal. 
Phase Detector Frequency 
(MHz) 
n/s 
PLL2 Phase Detector Frequency (PDF).  
This value is calculated as: 
PLL2 PDF = OSCin Frequency 
*(2
EN_PLL2_REF_2X
) / PLL2_R. 
VCO Frequency (MHz) 
n/a 
Internal VCO Frequency should be within 
the allowable range of the LMK048xxB 
device.   
This value is calculated as: 
VCO Frequency = PLL2 PDF * (PLL2_N * 
PLL2_P * VCO divider value). 
Doubler 
EN_PLL2_REF_2X 
PLL2 Doubler. 
0 = Bypass Doubler 
1 = Enable Doubler 
R Counter  
PLL2_R 
PLL2 R Counter value (1 to 4095). 
N Counter  
PLL2_N 
PLL2 N Counter value (1 to 262143). 
PLLN Prescaler  
PLL2_P 
PLL2 N Prescaler value (2 to 8).