Modules
Table 17-4. Input and Output Instructions (continued)
Syntax
Description
Operation
Z
N
C
V
out Rd,(Rs)
Output indirect
reg[rs] = Rd
-
-
-
-
For instructions using direct peripheral register addressing, an 8-bit address is embedded in the instruction
supporting direct access to 256 I/O ports in the range 0 to 255. Using the prefix instruction, the direct I/O
address can be extended to 16. 16-bit addressing of I/O is also possible using indirect addressing.
17.4.1.5.3 I/O Bit Access
In addition to reading and writing I/O ports using the input and output instructions, individual bits in the I/O
ports can be directly set, cleared, and tested using single instructions. This allows very fast and code-
efficient implementation of common bit-manipulation functions, without requiring the use of internal
registers.
shows the input and output instructions available.
Table 17-5. Input and Output Instructions
Syntax
Description
Operation
Z
N
C
V
iobclr #imm,[#addr]
I/O Bit Clear direct
reg[addr] &= ~2^imm
-
-
-
-
iobset #imm,[#addr]
I/O Bit Set direct
reg[addr] |= 2^imm
-
-
-
-
iobtst #imm,[#addr]
I/O Bit Test direct
reg[addr] & 2^imm
-
-
x
-
The clear and set instructions first perform an input operation from the addressed register, then modify the
selected bit only and output the resulting new value to the same register.
Note that it is only possible to select bits 0 to 7 in a register using the 3-bit immediate value encoded in
the instructions.
Because the instructions use only direct register addressing, an 8-bit address is embedded in the
instruction supporting direct access to 256 registers in the range 0 to 255. Using the prefix instruction, the
direct register address can be extended to 16-bit.
17.4.1.5.4 Arithmetic and Logical Operations
The arithmetic and logical operations operate on a destination operand in an integer register, while the
source can be either another integer register, or an 8-bit immediate operand.
shows the arithmetic and logical instructions.
Table 17-6. Arithmetic and Logical Instructions
Syntax
Description
Operation
Z
N
C
V
Dyadic instructions
add Rd,#simm
Add immediate
Rd += simm
x
x
x
x
cmp Rd,#simm
Compare immediate
Rd – simm
x
x
x
x
and Rd,#imm
AND immediate
Rd &= imm
x
x
0
0
or Rd,#imm
OR immediate
Rd |= imm
x
x
0
0
xor Rd,#imm
XOR immediate
Rd ^= imm
x
x
0
0
tst Rd,#imm
Test immediate
Rd & imm
x
x
0
0
add Rd,Rs
Add register
Rd += Rs
x
x
x
x
sub Rd,Rs
Subtract register
Rd -= Rs
x
x
x
x
subr Rd,Rs
Subtract reverse register
Rd = Rs – Rd
x
x
x
x
cmp Rd,Rs
Compare register
Rd – Rs
x
x
x
x
and Rd,Rs
AND register
Rd &= Rs
x
x
0
0
or Rd,Rs
OR register
Rd |= Rs
x
x
0
0
1194AUX – Sensor Controller with Digital and Analog Peripherals
SWCU117A – February 2015 – Revised March 2015
Copyright © 2015, Texas Instruments Incorporated