Factory Configuration (FCFG)
9.2.1.32 FLASH_PP Register (Offset = 184h) [reset = X]
FLASH_PP is shown in
and described in
Flash Program Pulse
Figure 9-53. FLASH_PP Register
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10
9
8
7
6
5
4
3
2
1
0
PUMP_SU
RESERVED
MAX_PP
R-X
R-0h
R-14h
Table 9-55. FLASH_PP Register Field Descriptions
Bit
Field
Type
Reset
Description
31-24
PUMP_SU
R
X
Pump read->non-read mode transition time in half-microseconds
(mainly for FPES).
23-16
RESERVED
R
0h
Software should not rely on the value of a reserved. Writing any
other value than the reset value may result in undefined behavior.
Reset holds trim value from production test.
15-0
MAX_PP
R
14h
Max program pulse limit per program operation. Value will be written
to FLASH:FSM_PRG_PUL.MAX_PRG_PUL when an erase/program
operation is initiated.