Texas Instruments AFE5809 Evaluation Module AFE5809EVM AFE5809EVM Datenbogen

Produktcode
AFE5809EVM
Seite von 63
TEST AFE5809
Figure 8. Ramp Waveform Output
8.2
Step 2: Single Tone FFT
Select Frequency from the display control on the TSW1400 GUI to display the FFT.
Connect Channel 1 of the AFE5809EVM to a signal generator through a BP filter. If a BP filter is not
present, the result is not good.
Set the amplitude of the signal generator to -25 dBm.
Set the frequency of the signal generator to the value in the "ADC Input Target Frequency" field of the
TSW GUI.
Change the window option to Hanning if using the onboard clock. This is because the input signal and
the onboard CMOS clock are noncoherent.
Press the Capture button to get the test result.
Repeat for Channel 2 through Channel 8.
10
AFE5809EVM Evaluation Module
SLOU338A – October 2012 – Revised November 2012
Copyright © 2012, Texas Instruments Incorporated