23 
Detect field strength intensity 
The actual field 
strength of the 
GSM signal is 
read out and 
displayed 
graphically. 
Values below 12 
indicate an insufficient signal strength. The antenna location should be improved. The 
value 99 stands for not ascertainable field strength, e.g. due to network loss or a 
damaged antenna. When the location of the antenna is changed, it takes approximately 
5 to 10 seconds until the field strength of the INSYS GSM small is updated.  
 
5.2.2 System Monitoring 
Software reset 
Using a software reset, the INSYS GSM small unregisters for a short period and re-
registers again daily to allow maintenance functions of the GSM provider. Enter the time 
interval after which another software reset should be performed (1 to 999 hours). 
Afterwards, the INSYS GSM small re-registers at the GSM network, if the PIN of the SIM 
card is stored. 
For the value “0” no software reset is performed. 
Attention!   When the INSYS GSM small has not been registered for a longer period, it 
can not update the updates from the GSM network provider and some 
functions may have errors.  
5.2.3 Connection Protocol 
For a data connection with a device outside the GSM network (analog modem or ISDN 
TA) the right protocol has to be selected. This setting is not important for data 
connections with a GSM device. 
 