6. Function Description 
6.3.3 Automatic Reset 
To avoid a faulty registering status of the INSYS GSM small during infrastructure changes 
of the GSM network (software updates of the databases, temporary network extensions, 
e.g. for fairs), the device should be periodically unregistered and re-registered, or re-
started and initialized. 
 
For this, the following command must be configured in addition: 
AT^SCFG="AutoExec",1,1,2,0,"AT+CFUN=1,1","024:00:00" 
 
After the set time has expired (in the example 24 hours), the INSYS GSM small carries out 
a software reset. After this reset, the configured functions will again be performed. 
This is indicated at the serial interface: 
^SCFG: "AutoExec",1,1,2,0,"AT+FUN=1,1" 
 
The setting can be deactivated by entering the following: 
AT^SCFG=“AutoExec“,0,10.2 
 
The settings of this command are only stored with the command AT^SMSO. 
 
For time-controlled functions, the internal timers start from the beginning after a restart 
or a reset. This also applies if ATZ or AT&F are entered! 
 
Therefore, with these examples all 3 actions for time-controlled routines are in use: 
AT^SCFG="AutoExec",1,1,0,0,"AT+COPS=0","000:00:06" 
AT^SCFG="AutoExec",1,1,1,0,"AT+CPIN=0000","000:00:10" 
AT^SCFG="AutoExec",1,1,2,0,"AT+CFUN=1,1","024:00:00" 
 
6.3.4  Alarm Signal Via DTR Control Line 
With the command AT^SCFG, you have the possibility to configure an action. This can be 
used to establish a data connection or to send an SMS. 
The action is performed as soon as the DTR control line is active (e.g. when a COM port is 
open at a PC). 
 
 
 
Version  1.00 / 09.04