Testo 882 , 33 Hz thermography camera, -20 to +350 °C, 320 x 240 pix bolometer matrix 0560 0882 Benutzerhandbuch
Produktcode
0560 0882
6 Using the product
25
- The changes are saved.
Moisture
The surface humidity is calculated using the manually entered
dewpoint temperature and the measured surface temperatures. In
the display, the areas that are at risk of developing mould are
shown using a special colour palette:
Colour
The surface humidity is calculated using the manually entered
dewpoint temperature and the measured surface temperatures. In
the display, the areas that are at risk of developing mould are
shown using a special colour palette:
Colour
Surface moisture
Assessment
green
0 - 64 %
noncritical
yellow-
orange
orange
65 - 80 %
potentially critical
red >80
%
critical
If this function is activated (
), the quick select buttons are
permanently assigned the
Dewpoint
and
Emissivity...
functions.
At the upper edge of the display, the relative air humidity, air
temperature and dewpoint temperature are shown.
1.
temperature and dewpoint temperature are shown.
1.
[OK]
|
Measurement
|
[OK]
|
Humidity
|
[OK]
.
- The
Dewpoint
dialogue is opened. The dewpoint temperature
can be entered.
If the image is to be evaluated using the IRSoft software,
the values for the ambient temperature and ambient
humidity must be entered. If these values are missing, the
image cannot be evaluated with the software!
the values for the ambient temperature and ambient
humidity must be entered. If these values are missing, the
image cannot be evaluated with the software!
2.
Move
Joystick
up/down to select the desired option.
- The selected option has an orange border.
3.
3.
Confirm the selection with
[OK]
.
- The selected number is highlighted orange.
4.
4.
Move
Joystick
up/down to set the desired value. Move
Joystick
right/left to change between the numbers.
5.
Confirm the entry with
[OK]
.
6.
Confirm the settings with
Apply
.
Measuring range
The measuring range can be set to adapt to the respective area of
application.
1.
The measuring range can be set to adapt to the respective area of
application.
1.
[OK]
|
Measurement
|
[OK]
|
Measurement range
.
2.
Select the desired temperature range and confirm with
[OK]
.