Testo 882 , 33 Hz thermography camera, -20 to +350 °C, 320 x 240 pix bolometer matrix 0560 0882 User Manual

Product codes
0560 0882
Page of 42
6 Using the product 
 
 
25 
-  The changes are saved. 
Moisture 
The surface humidity is calculated using the manually entered 
dewpoint temperature and the measured surface temperatures. In 
the display, the areas that are at risk of developing mould are 
shown using a special colour palette: 
Colour  
Surface moisture 
Assessment 
green 
0 - 64 % 
noncritical 
yellow-
orange 
65 - 80 % 
potentially critical 
red >80 
critical 
 
If this function is activated (
), the quick select buttons are 
permanently assigned the 
Dewpoint
 and 
Emissivity...
 functions.  
At the upper edge of the display, the relative air humidity, air 
temperature and dewpoint temperature are shown. 
1.
 
[OK] 
Measurement
 | 
[OK]
 | 
Humidity
 | 
[OK]
- The 
Dewpoint
 dialogue is opened. The dewpoint temperature 
can be entered.  
 
 
If the image is to be evaluated using the IRSoft software, 
the values for the ambient temperature and ambient 
humidity must be entered. If these values are missing, the 
image cannot be evaluated with the software! 
 
2.
  Move 
Joystick
 up/down to select the desired option. 
-  The selected option has an orange border. 
3.
  Confirm the selection with 
[OK]
-  The selected number is highlighted orange. 
4.
  Move 
Joystick
 up/down to set the desired value. Move 
Joystick
 right/left to change between the numbers. 
5.
  Confirm the entry with 
[OK]
6.
  Confirm the settings with 
Apply
Measuring range 
The measuring range can be set to adapt to the respective area of 
application.  
1.
 
[OK] 
Measurement
 | 
[OK]
 | 
Measurement range
2.
  Select the desired temperature range and confirm with 
[OK]