Meilhaus Electronic Logian-16 Logic-Analyzer, Logic analyzer Logian-16 Datenbogen

Produktcode
Logian-16
Seite von 32
Logian-16 
User  Manual 
 
 
Logian-16 User
’s Manual
 
Page 10 
Table 1-5: Definitions and Functions of pins for advance models (2). 
VDD 
Voltage Drain 
(Semiconductor)   
Provides  +3.3  V  for  external  modules  by  draining 
voltage from the Logic Analyzer. 
IOA 
Ext. I/O Module A 
Transmits  signals  from  an  external model  or  device 
not being tested. 
IOB 
Ext. I/O Module B 
Same as 
IOA
IOC 
Ext. I/O Module C 
Same as 
IOA
GND 
Ground 
Grounds external devices, in sequence 
 
1.3  Hardware Specifications 
Table 1-6: Hardware specifications of ODM-A Series. 
Items\Type
 
ODM-16128U
 
Interface
 
USB 2.0 (1.1) 
Operating System
 
Win 95/NT/98SE/ME/2000/XP/2003 
Power Supply
 
USB 1.1 (USB 2.0 Recommended) 
Channels
 
16 
Bandwidth
 
75MHz 
Memory
 
4M Bits 
Memory Depth   
(Per Channel)
 
128kBit 
Internal Clock Rate
 
(asynchronous)
 
100 Hz ~ 200 MHz 
Max External Clock
 
(synchronous)
 
Max 100MHz 
Trigger Channels
 
16 Channels 
Trigger Condition
 
Edge/Pattern 
Pre-Trigger/ 
Post-Trigger
 
Yes 
Trigger Level
 
1 Level 
Trigger Count
 
1-65535 
Max Trigger Page
 
Max 8192 
Enable Channel
 
16 
Buses Data Decoded
 
Yes 
Enable Delay
 
Start: Edge and Pattern 
End: 1-65535 
Compression
 
16 Channel 
Compression 
1-255