Gw Instek PEL-3211 Electronic Load PEL-3211 Datenbogen

Produktcode
PEL-3211
Seite von 174
 
 
PEL-3000 Programming Manual 
68
 
Parameter  
HIGH 
High range 
 
MIDDLE or MIDD 
Middle range 
 
LOW 
Low range 
Return parameter  High 
High range 
 
Mid 
Middle range 
 
Low 
Low range 
Example 
:CRANge LOW 
Sets the current range to Low. 
Query example 
:CRANge? 
>Low 
The current range is set to Low. 
[:MODE]:VRANge 
Set
Query
 
 
Description 
Configures the voltage range for all the applicable 
operating modes.  
Syntax 
[:MODE]:VRANge {HIGH | LOW } 
Query Syntax 
[:MODE]:VRANge? 
Parameter 
HIGH 
High range 
 
LOW 
Low range 
Return parameter  High 
High range 
 
Low 
Low range 
Example 
:VRANge LOW 
Sets the voltage range to Low. 
Query example 
:VRANge? 
>LOW 
The voltage range is set to Low. 
[:MODE]:RESPonse
 
 
Set
Query
 
 
Description 
Returns the CV Mode response speed. Fast is the 
default response speed. 
Syntax 
[:MODE]:RESPonse { FAST | SLOW } 
Query Syntax 
[:MODE]:RESPonse?