Gw Instek PEL-3211 Electronic Load PEL-3211 Datenbogen

Produktcode
PEL-3211
Seite von 119
 
GETTING STARTED 
29 
 
System
Info
Load
Interface
Time Set
 
LOAD
RS232
03/Sep/2012
 
Other
9
Hour
0
Year
2012
Minute
Day
Month
9
3
Date/Time
Date
 
Load Wiring 
 
Wire Gauge 
considerations  
Before connecting the unit to a power source, 
the wire gauge must be taken into account. 
Load wires must be large enough to resist 
overheating when a short-circuit condition 
occurs as well as to maintain a good regulation. 
The size, polarity and length of a wire are all 
factors in determining if a wire will withstand 
short circuiting.     
 
Wires that are selected must be large enough to 
withstand a short circuit and limit voltage 
drops to no more than 2V per wire. Use the 
table below to help make a suitable selection.  
 
 
 AWG 
Gauge 
Conduct or 
Diameter 
mm 
Ohms per 
km 
Max  amps 
for chassis 
wiring 
 0000 
11.684 
0.16072 
380 
 000 
10.4038 
0.2027 
328 
 00 
9.26592 
0.25551 
283 
 0 
8.25246 
0.32242 
245 
 1 
7.34822 
0.40639 
211