<Model Menu (Airplane/Glider Functions)>
  When setting a rate selection switch, move 
the cursor to the switch item and touch the 
RTN button to access the selection screen. 
Select the switch and set its ON direction. 
(Always ON at "--" setting)
*For a description of the switch selection method, see the 
description at the back of this manual.
●Gyro type selection
  Move the cursor to the gyro type selection 
item and touch the RTN button to switch to 
the data input mode. Select the gyro type 
by scrolling the touch sensor. 
  [GY]: When a Futaba GYA gyro is used
  [NORM]: When using something other than 
Futaba GYA gyro is used.
  Touch the RTN button to change the gyro 
type and return to the cursor mode.
*When a Futaba GYA gyro is used and [GY] type is selected, 
the sensitivity set value is directly read in both the AVCS 
and NORM modes.
●Operation mode selection (GYA gyro)
  Move the cursor to the operation mode 
selection item and touch the RTN button 
to switch to the data input mode. Select 
the operation mode by scrolling the touch 
sensor. 
  [AVCS]: AVCS mode
  [NORM]: Normal mode
  Touch the RTN button to change the 
operation mode and return to the cursor 
mode.
 
●Sensitivity setting
  Move the cursor to the sensitivity icon and 
touch the RTN button to switch to the data 
input mode. 
  Adjust the  sensitivity by scrolling the touch 
sensor. 
  Initial value: 0%
  Adjustment range: 0~100%
*When the RTN button is touched for one second, the 
sensitivity is reset to the initial value.)
  Touch the RTN button to return to the cursor 
mode.
(Example) Setting three axis using a GYA430 and GYA431 (2)
● Wing type: Aileron 2 servos mounted fuselage selected
● Set Gyro 1 (GYA431AIL): CH5, Gyro 2 (GYA431ELE): CH7, Gyro 3 (GYA430RUD): CH8 at 
the Function menu of the Linkage menu.
●  Rate 1 [OFF][GY][SE][NORM][60%][NORM][60%][NORM][60%]
  Rate 2 [INH]
  Rate 3 [OFF][GY][SE][AVCS][60%][AVCS][60%][AVCS][60%]
*Set so that Rate 1 is turned on at the back position of switch E and Rate 3 is turned ON at the front 
position. Since switch E is turned OFF at the center, Rate 2 remains [INH].
R7008SB
Rudder servo
Elevator servo
GYA430
GYA431
GYA431
Aileron servo
S.BUS/S.BUS2 port
*When a S.BUS port is used 
R7008SB CH Mode is set to 
ModeB [D]. 
GAIN 0%
AVCS
NORMAL
When AVCS is used we 
recommend that the 
sensitivity CH be set to 
the 3-position.