Maico Ventilatoren Ventilation technology White IPX5 840205 Datenbogen

Produktcode
840205
Seite von 38
7. Installation 
│ gb 
 
17 
7. Installation 
 
7.1 Installing housing 
1.  Insert housing [1] into wall breakthrough/ 
wall sleeve (TOP must be at top). 
 
2.  Align housing horizontally and mark the 
two dowel holes ( arrows). 
3.  Remove housing [1], drill M6 dowel holes 
with a Ø of 6 mm and insert dowels. 
4.  Push cable grommet [3] carefully out of 
housing and remove. 
 
NOTICE 
Danger of short circuits and 
damage to unit! Water will 
penetrate if the power cable  
is incorrectly fed into the fan 
housing or if the cable grom-
met is not fitted correctly.
 
Cut off cable grommet cap [3] 
such that the cable grommet fits 
tightly round the power cable. 
Cut off at least 5 mm of the cap 
(power cable can bend better 
and electronics cover [4] can be 
positioned correctly). 
Fit cable grommet [3] correctly, 
seal on both sides if required. 
 
 
 
 
 
5.  Insert cable grommet into housing. 
 
Guide power cable into connection 
area such that the cable grommet  
fits around the cable sheathing 
completely and does not penetrate 
too far into the connection area. 
 
7.2 Electrical connection 
 
DANGER 
Danger to life from electric 
shock. 
Switch the mains fuse off. 
 
NOTICE 
Unit damage in the case of 
short-circuits. 
Insulate PE conductor and 
unneeded cable cores. 
 
1.  Only lay single cable cores in the unit. To 
do this, reduce power cable sheathing to a 
length of 100 mm. Strip single cable cores 
to 9 to 10 mm. 
2.  Insert housing [1] into wall breakthrough/ 
wall sleeve and secure with two screws. 
Do not insert the housing such that it is 
twisted or crushed. Make sure you use 
mounting material which is sized for the 
purpose. 
 
3.  Electrically connect power cable to spring 
clip [13] according to connection wiring 
diagram [14], also see wiring diagrams in 
Chapter 13.