17. From inside of the heater body, push one of the leads through the black rubber gasket and into the terminal box. The gasket has two small holes in 
it and one wire per hole should be inserted (the sleeving needs to be pulled back so only the white wire comes through) and push it firmly into either 
one of the terminals. Hold in place and tighten the screw fully (Fig. 17). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
18. Push the other emitter lead through the second hole in the gasket and fit to the second terminal of the connector 
block (Fig. 17). The connector block can now be returned to its locating lugs and the screws checked for tightness. 
Replace the connector block retaining bridge and screw (Fig. 18). 
 
 
19. The back plate can now be placed on the back of the heater and the locating lugs pushed in as shown in Fig. 19. 
 
 
20. The other end casing can be aligned and ensuring the lead is not going to get trapped (as  step  15!)  and is positioned as shown in Fig 20,  push the 
end  casing  into  place.  It  is  recommended  that  the  heater  is  stood  up  on  its  fixed  end  and  downward  force  applied  to  ensure  everything  goes  back   
together correctly (Fig. 21). 
Fig. 23 
Fig. 22 
Fig. 19 
Fig. 20 
Fig. 21 
21.  If  the  leads  are  free  to  move  and  the  guard  and 
side  reflectors  are  in  order,    the  back  plate  should  be 
closed  and  all  screws  refitted  and  checked  for  tight-
ness (Fig. 22). 
 
 
22. Make a final check in the terminal box that all of the 
wires  are  secure  and  replace  the  cover  and  refit  the 
screws.
 
23. The heater can now be returned to its original mounting position and the mains power reconnected.
 
Fig. 17 
Fig. 18 
RETAINING BRIDGE 
I n s t a l l a t i o n  
 
The Rio IP heater is fitted with 5.0 meters of supply cable and a moulded plug, therefore it is        
unnecessary  to  open the terminal  box  in  order  to carry  out  normal installation  of  this  product 
and should not be interfered with. 
 

We recommend using a RCD where applicable. 
 

Please observe the minimum safe distance between the heater body and any inflammable 
surfaces. 
 

If the supply cord becomes damaged, it must be replaced by the manufacturer, its service 
agent or a similar qualified person in order to avoid a hazard. 
 

When  the  electrical connection  is  outside,  it is  recommended that a  waterproof  socket is 
used for the connection. Otherwise, the plug should be connected to a socket indoors. 
 

If in any doubt, please contact a suitably qualified electrician. 
 
 
 
M o u n t i n g 
 

The Rio IP models can be mounted in a horizontal (Fig. A) or angled (Fig. D) manner. 
 

When mounting the Rio IP horizontally, do not position the heater at an angle more than 
90° and less than 30° from the vertical mounting surface as shown in Fig. A. 
 

When  angled  mounting  the  Rio  IP,  ensure  to  leave  a  gap  between  the  heater  and    
mounting surface (See Fig. D - DIM ‘A’). The heater should always be angled downwards 
when mounting this way with the terminal box at the bottom of the heater - see Fig. D. Do 
not  position  the  heater  at  an  angle  more than  45°  and  less than  30°  to  the  horizontal  as 
shown. 
 

Always  allow  the  heater  to  cool  before  attempting  to  reposition/move.  Never  attempt  to 
move the heater while it is switched on! 
 

Observe  the  minimum  safe  distance  between  the  heater  body  and  inflammable  surfaces 
and objects when mounting. 
 

Please refer to Table 1 for the recommended positioning of the heater. 
 

Keep out of the reach of children. 
 
 
1.  Securely  fasten  the  Rio  IP  bracket  to  the  mounting  surface  using  the  fixing  holes  in  the 
bracket. Please refer to Table 1 for recommended positioning of the heater. 
 
2. Fix in the required angular position by tightening the fixing bolt on the bracket at the rear of 
the heater. 
 
3. The Rio IP bracket can be used to adjust the direction of the heater up and down (see Fig. 
B)  and  side  to  side  (see  Fig.  C).  This  is  done  by  loosening  the  bolts  fixing  the  heater  to  the 
bracket, and then retightening once the correct position is achieved. 
 
Always isolate the heater from the mains supply when adjusting the angular position. 
M a i n t e n a n c e  
 
In the event of heater failure, or for spare parts or advice, please contact the manufacturer in the first instance. 
 

Disconnect from the mains before commencing any maintenance procedure including cleaning. 
 

To ensure optimum heat effectiveness, it is recommended that that the guard and emitter are removed and the reflector is wiped with a lint-free cloth 
before reassembling should the reflector show signs of dust or dirt. 
Fig. A 
Fig. B 
Fig. C 
Fig. D 
HORIZONTAL MOUNTING 
ANGLED MOUNTING