17. From inside of the heater body, push one of the leads through the black rubber gasket and into the terminal box. The gasket has two small holes in
it and one wire per hole should be inserted (the sleeving needs to be pulled back so only the white wire comes through) and push it firmly into either
one of the terminals. Hold in place and tighten the screw fully (Fig. 17).
it and one wire per hole should be inserted (the sleeving needs to be pulled back so only the white wire comes through) and push it firmly into either
one of the terminals. Hold in place and tighten the screw fully (Fig. 17).
18. Push the other emitter lead through the second hole in the gasket and fit to the second terminal of the connector
block (Fig. 17). The connector block can now be returned to its locating lugs and the screws checked for tightness.
Replace the connector block retaining bridge and screw (Fig. 18).
19. The back plate can now be placed on the back of the heater and the locating lugs pushed in as shown in Fig. 19.
20. The other end casing can be aligned and ensuring the lead is not going to get trapped (as step 15!) and is positioned as shown in Fig 20, push the
end casing into place. It is recommended that the heater is stood up on its fixed end and downward force applied to ensure everything goes back
together correctly (Fig. 21).
Fig. 23
Fig. 22
Fig. 19
Fig. 20
Fig. 21
21. If the leads are free to move and the guard and
side reflectors are in order, the back plate should be
closed and all screws refitted and checked for tight-
ness (Fig. 22).
22. Make a final check in the terminal box that all of the
wires are secure and replace the cover and refit the
screws.
side reflectors are in order, the back plate should be
closed and all screws refitted and checked for tight-
ness (Fig. 22).
22. Make a final check in the terminal box that all of the
wires are secure and replace the cover and refit the
screws.
23. The heater can now be returned to its original mounting position and the mains power reconnected.
6
Fig. 17
Fig. 18
RETAINING BRIDGE
I n s t a l l a t i o n
The Rio IP heater is fitted with 5.0 meters of supply cable and a moulded plug, therefore it is
unnecessary to open the terminal box in order to carry out normal installation of this product
and should not be interfered with.
We recommend using a RCD where applicable.
Please observe the minimum safe distance between the heater body and any inflammable
surfaces.
surfaces.
If the supply cord becomes damaged, it must be replaced by the manufacturer, its service
agent or a similar qualified person in order to avoid a hazard.
agent or a similar qualified person in order to avoid a hazard.
When the electrical connection is outside, it is recommended that a waterproof socket is
used for the connection. Otherwise, the plug should be connected to a socket indoors.
used for the connection. Otherwise, the plug should be connected to a socket indoors.
If in any doubt, please contact a suitably qualified electrician.
M o u n t i n g
The Rio IP models can be mounted in a horizontal (Fig. A) or angled (Fig. D) manner.
When mounting the Rio IP horizontally, do not position the heater at an angle more than
90° and less than 30° from the vertical mounting surface as shown in Fig. A.
90° and less than 30° from the vertical mounting surface as shown in Fig. A.
When angled mounting the Rio IP, ensure to leave a gap between the heater and
mounting surface (See Fig. D - DIM ‘A’). The heater should always be angled downwards
when mounting this way with the terminal box at the bottom of the heater - see Fig. D. Do
not position the heater at an angle more than 45° and less than 30° to the horizontal as
shown.
mounting surface (See Fig. D - DIM ‘A’). The heater should always be angled downwards
when mounting this way with the terminal box at the bottom of the heater - see Fig. D. Do
not position the heater at an angle more than 45° and less than 30° to the horizontal as
shown.
Always allow the heater to cool before attempting to reposition/move. Never attempt to
move the heater while it is switched on!
move the heater while it is switched on!
Observe the minimum safe distance between the heater body and inflammable surfaces
and objects when mounting.
and objects when mounting.
Please refer to Table 1 for the recommended positioning of the heater.
Keep out of the reach of children.
1. Securely fasten the Rio IP bracket to the mounting surface using the fixing holes in the
bracket. Please refer to Table 1 for recommended positioning of the heater.
2. Fix in the required angular position by tightening the fixing bolt on the bracket at the rear of
the heater.
3. The Rio IP bracket can be used to adjust the direction of the heater up and down (see Fig.
B) and side to side (see Fig. C). This is done by loosening the bolts fixing the heater to the
bracket, and then retightening once the correct position is achieved.
Always isolate the heater from the mains supply when adjusting the angular position.
M a i n t e n a n c e
In the event of heater failure, or for spare parts or advice, please contact the manufacturer in the first instance.
Disconnect from the mains before commencing any maintenance procedure including cleaning.
To ensure optimum heat effectiveness, it is recommended that that the guard and emitter are removed and the reflector is wiped with a lint-free cloth
before reassembling should the reflector show signs of dust or dirt.
before reassembling should the reflector show signs of dust or dirt.