Using the Web Configuration and Management Interface 
Manual Documentation Number ES1A -2907m        
pn6909-rev003 
17 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
TCP Sockets
    
Select TCP Sockets to implement Direct IP Mode using TCP. When using 
TCP Sockets your converter can be configured as a TCP server or TCP 
client
.  
TCP Server Settings  
If your ES1A is configured as a TCP server, other network devices 
can initiate a TCP connection with the serial device connected to the 
ES1A serial port. (This is also referred to as reverse telnet.) Network 
devices initiating connections must be configured with the IP 
address of the ES1A and the TCP port number associated with its 
serial port.  
After selecting TCP Sockets, click Apply to return to the Serial 
Port Configuration
 page. Select the TCP Server Settings as 
required by your application. 
  
Figure 9. 
TCP Server Settings 
For each option, the TCP port number is shown. You can also 
Enable TCP Keep Alive for each selection. (If Enable Keep Alive 
is selected the connections is maintained even if no data is being 
sent.) 
TCP Client Settings  
If your ES1A is configured as a TCP client it will automatically 
establish a bi-directional TCP connection between the serial device 
and a server or other networked device. Selecting Automatically 
establish TCP connections
 enables this feature and its 
configuration options become available.