Using the Web Configuration and Management Interface 
18 
Manual Documentation Number:  ES1A -2907m       
pn6909-rev003 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com 
B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com 
 
Figure 10.  TCP Client Settings 
Consult the Tutorial and online Help for more detail. 
UDP Sockets
    
Select  UDP Sockets to implement Direct IP Mode using UDP  protocol. 
When using UDP Sockets your converter can be configured as a UDP server 
or UDP client.  
UDP Server Settings  
If your ES1A is configured as a UDP server, other network devices 
can initiate a UDP connection with the serial device connected to the 
ES1A serial port. Network devices initiating connections must be 
configured with the IP address of the ES1A and the UDP port 
number associated with its serial port.  
After selecting UDP Sockets, click Apply to return to the Serial 
Port Configuration
 page. Select the TCP Server Settings as 
required by your application.