CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FORM THE
STOVE AND OUTSIDE MINIMUM CLEARANCES.
CAUTION: REPLACE FIREBRICKS BEFORE
FIRING WOODSTOVE. POSITION FIREBRICKS
SO NO GAPS REMAIN  BETWEEN BRICKS.
LOCATING STOVE
Fig. 1 – TOP VIEW  Minimum Clearance Dimensions from Combustible Surfaces
FLOOR
PROTECTOR
DASHED LINES SHOW HORIZONTAL CHIMNEY CONNECTOR
AND ADDITIONAL FLOOR PROTECTOR REQUIRED BENEATH
                                  AND 
EXTENDING 2” BEYOND EACH SIDE
NON COMBUSTIBLE CONSTRUCTION IN ACCORDANCE WITH NFPA 211
BACKWALL
SIDEWALL
8"min.
17"
41"
16"min.
6"min.
23"
 15"
min.
12"min
TOP VIEW
  35"
CAUTION: (FIRE HAZARD) CARPETING AND
OTHER COMBUSTIBLE MATERIAL SHALL NOT
COVER THE FLOOR PROTECTOR. THESE
MATERIALS MUST REMAIN OUTSIDE OF
COMBUSTIBLE CLEARANCES, SEE FIG. 1 – 3.
2. The stove must have its own flue. DO NOT
CONNECT THIS UNIT TO A CHIMNEY
FLUE SERVING OTHER APPLIANCES.
3. After observing the clearances to combustible
materials (figures 1–3), locate your floor
protector accordingly (figure 1) and carefully
place the stove in your selected location.
Install stove pipe, elbows, and thimble as
required, utilizing either a recently cleaned and
inspected 6”  masonry chimney or a 6” i.d.
listed chimney.
4. Use 6” round black stove pipe, not
galvanized stove pipe. Secure pipe sections
with three (3) sheet metal screws in each stove
pipe and/or elbow joint to firmly hold the pipe
sections together. DO NOT CONNECT THIS
STOVE TO ANY AIR DISTRIBUTION OR
DUCT SYSTEM.
5. Recheck clearances from the stove,
connector stove pipe, and corner clearances
using the illustrations in figures 1–3 and
your local building codes or fire protection
ordinances.
NOTE: Drywall faced with brick or stone must
be considered a combustible surface.
Continued on next page
6. DO NOT INSTALL THIS STOVE IN A MOBILE
HOME, MANUFACTURED HOME, TRAILER OR
TENT
 
– NO  EXCEPTIONS! (HUD Federal
Standard: 24 CFR Ch.XX)
7. The clearances provided are minimum
dimensions determined by Omni Test Labora-
tories, Inc., the manufacturer ’s testing
laboratory. Installation of  this stove must
comply with the latest edition of NFPA 211 for
reduced clearances and/or your local building
code rulings. Use whichever minimum
dimensions are LARGEST.
Failure to follow these minimum clearance
requirements may result in an unsafe
installation and could cause a fire.
8. This stove meets U.S. Test Standard:
UL 1482-1996 and Canadian Test Standard
ULC-S627.
9. Always locate stove to provide a source of fresh
air into the room where the unit is installed.
Failure to do so may result in air starvation of
other fuel burning appliances and the possible
development of hazardous conditions.