B&B Electronics RS-232 to J1939 Converter CE 1939STB Benutzerhandbuch

Seite von 40
12  1939STB4600 
Manual 
 
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 
B&B Electronics Ltd – Westlink Commercial  Park – Oranmore, Galway, Ireland – Ph +353 91 792444 – Fax +353 91 792445 
 
 
RS-232 Baud Rate Change cont’d.
 
 
Bit 2 stop bit works in conjunction with bits 1 and bit 0. 
 
Table 16.  Stop Bit Setup
 
Bit 2 
Word length (bits) 
Stop bit length 
  0 
       5, 6, 7, 8 
           1* 
  1 
           5 
          1½ 
  1 
        6, 7, 8 
           2 
  
* Setup default value. 
 
Bits 1 and 0 set the word length. 
 
Table 17.  Word Length 
Bit 1 
Bit 2 
Word  length 
          5 
          6  
          7 
          8* 
 
* Setup default value.