RS-232 Baud Rate Change cont’d. 
 
Baud Change; Parity, word length, stop bits. 
 
 
Byte 5 (UB3) 
 
 
UB3 sets the LCR register on the UART 
 
Table 14.  Byte 5  (UB3) 
Bit 7 
Bit 6 
Bit 5 
Bit 4 
Bit 3 
Bit 2  
Bit 1 
Bit 0 
Divisor 
latch 
Set 
break 
Set 
parity 
Even 
parity 
Parity 
enable 
Stop 
bits 
Word 
length 1 
Word 
length 0 
 
 
Bit 7 =   1 allows baud rate divisor to be changed. 
 
0 baud rate change is blocked. 
 
Bit seven should not be set. The setting and resetting of this bit is 
handled internally. 
 
Bit 6 =   1 forces the transmitter output to a logic 0 for alerting the remote  
 
receiver to a line break. 
 
0 No break condition. 
 
Bits 5, 4, 3 work together to set parity.  
 
 
 
 
 
 
 
 
 
 
 
Table 15.  Parity Setup 
Bit 5 
Bit 4 
Bit 3 
Parity Selection 
   X 
   X 
   0 
No parity * 
    0 
   0 
   1 
Odd parity 
    0 
   1 
   1 
Even parity 
    1 
   0 
   1 
Force parity “1” 
    1 
   1 
   1 
Force parity “0” 
 
  
* Setup Default Value.