Administrator Operations on the  Remote Control Panel (separately sold)
Service
 AG-CPD15 Operating Time
Use this function to view the 
operating time of this unit. 
(unit : H)
 FAN Operating Time
Use this function to view the operating 
time of the fan.
(unit : H)
 CAM1 Operating Time
Use this function to view the operating 
time of the Color Camera.
(unit : H)
 AG-RCP30 Operating Time
Use this function to view the operating 
time of the Remote Control Panel.
(unit : H)
 LCD Lighting Time
Use this function to view the 
cumulative lighting time of the LCD 
panel. 
(unit : H)
 AG-CPD15  Version
Use this function to view the version 
of this unit.
 BIOS Creation Date
Use this function to view the BIOS 
creation date. (Month/Day/Year)
 Microcontroller  Version
Use this function to view the version 
of the microprocessor.
 AG-RCP30  Version
Use this function to view the version 
of the Remote Control Panel.
Operations
 Version  Up
For details on obtaining version 
upgrade files, consult your supplier. 
Make sure to use a computer 
beforehand to save the version 
upgrade file you obtain in the root 
directory
 of a P2 card or USB 
memory device.
1.  Insert the P2 card or connect 
the USB memory device to this 
unit.
2.  Select [Service] - [Operations] 
- [Version Up], and press [ ] 
to confirm the entry.
A confirmation dialog box appears.
3.  Select “YES”, and accept by 
pressing the [ ] button.
The version upgrade is performed, 
and this unit automatically restarts.
Notes: 
•  Do not make button operations or 
turn the power off during a version 
upgrade. 
•  An error screen appears if the 
version upgrade fails. (see “Error 
messages” on pages 115, 116, 119)
Administrator Setup 
(continued)
∗  Version upgrade cannot be performed when the following conditions exist in the 
root directory.
 
• If a DATA folder is present
 
• If multiple version upgrade files (.VUP extension) are present