Whirlpool KR-28 Benutzerhandbuch

Seite von 29
- 13 -
DIRECT SPARK IGNITION CONTROL
Electrical Shock Hazard
Voltage is present during these tests.
WARNING
COMPONENT TESTING
SECTION 3
SECTION 3
SECTION 3
SECTION 3
SECTION 3
TEST PROCEDURE
Voltage Tests
Bake Function
1.
Set the voltmeter to read 120 VAC.
2.
Program the range for the Bake operation.
3.
If the top burners spark, proceed to step 4.
Touch the test leads to the J1 connector at
terminals 4 (white) and 10 (black). The AC
voltmeter should indicate 120 VAC. If not,
check for the proper voltage at the power
supply outlet, and check the main wiring
harness.
J1 Connector
4 (white)
10 (black)
J1 Connector
4.
Touch the test leads to the J1 connector at
terminals 4 (white) and 6 (red/white). The
AC voltmeter should indicate 120 VAC. If
not, check the electronic oven control for
proper operation.
J1 Connector
6 (red/white)
4 (white)
N
L1
BK
BK
P1-4
P1-5
OVEN
TEMP
SENSOR
V
V
P2-4
R
BAKE VALVE
W
OR
R
P2-1
OVEN CONTROL (ERC)
BROIL
RELAY
BAKE
RELAY
J1
6
4 3 2 1
7
9
10
10-PIN CONNECTOR
GND BAKE BROIL
DIRECT SPARK 
IGNITION CONTROL
Bake Strip Circuit