When power is applied to the range, a safety delay
of 40 seconds takes place before the direct spark
ignition control becomes operational. The opera-
tion will last for a period of 4 seconds, and the direct
spark ignition will again turn off (see the “Timing
Chart” for the oven burners on page 10).
4.
Touch the test leads to the J1 connector at
terminals 4 (white) and 7 (blue/white). The
AC voltmeter should indicate 120 VAC. If
not, check the electronic oven control for
proper operation.
5.
Set the voltmeter to read between 8 and
18 volts DC.
2 (orange) 3 (blue)
J1 Connector
6.
Touch the test leads to the J1 connector at
terminals 2 (orange) and 3 (blue). The DC
voltmeter should indicate between 8 and
18 volts DC*. If not, replace the DSI con-
trol.