Henkel LOCTITE 97504 Benutzerhandbuch

Seite von 94
73 
 
3    Operation 
3.8.3 
Automatic mixer flush cycle (optional)  
If the optional dispense gun docking station is used, an automatic mixer flush 
cycle can be actuated to prevent any undesired reaction of product components 
during idle periods.  
 
The electronic pump controller is equipped with a sensor which detects the presence 
of the dispense gun in the docking station and actuates the automatic mixer flush 
cycle after a preset time delay. 
 
Setup of flush cycle time is described in the following menu item. 
 
Automatic mixer flush setup: 
•  With the dispensing station in ready state, push * button twice - display indicates 
enter password
•  Enter password, see Section 3.8.1. 
• Push OK button - display indicates Automatic mixer flush 
 
 
•  Use arrow keys to enter desired value. 
Arrow key assignment / setting range: 
left: -10; right: +10; up: +1; down: -1; setting 
range 1 - 60 
• Push OK button to save the setting – display indicates "next menu item". Push 
ESC key to leave the service menu – display indicates Operation
Recommendation: Time setting should be considerably less than working life (see 
information on product packaging) 
 
Automatic flushing consumes product. If operational readiness of 
the system is to be maintained over a longer period of time, a 
sufficient supply of product needs to be available in the two 
containers. 
 If the dispensing station switches off due to lack of product, no 
dispense gun flushing cycle will be actuated. Accidental curing may 
occur. 
Automatic
Flushing Interval
OK/ESC
after 10 min.