Henkel LOCTITE 97504 Benutzerhandbuch

Seite von 94
75 
 
3    Operation 
3.8.5 
Enter calibration factor  
The capacity of pump B is calibrated to ensure accurate control and consistency of 
Part A and Part B mixing ratios.  
The capacity of pump A is the reference value (100%). For determination of the 
calibration factor proceed as described in Section 3.4. 
Enter calibration factor: 
•  With the dispensing station in ready state, push * button twice - display indicates 
Enter password
•  Enter password, see Section 3.8.1. 
•  Push OK button three times - display indicates Calibration factor. 
 
 
•  Use arrow keys to enter desired value. 
Arrow key assignment / setting range: 
left: -10; right: +10; up: +1; 
down: -1;  setting range: 70 – 140. 
• Push OK button to save the setting – display indicates "next menu item". Push 
ESC key to leave the service menu – display indicates Operation
3.8.6 
Select User Interface language 
Messages can be displayed in German or in English. 
Interface language setup: 
•  With the dispensing station in ready state, push * button twice - display indicates 
Enter password
•  Enter password, see Section 3.8.1. 
• Push OK button 4 times - display indicates Language selection 
 
 
or 
The following languages can be 
adjusted: 
– Deutsch 
– French 
– Italian 
– Portuguese 
•  Use arrow keys to enter desired value. 
Arrow key assignment / setting range: left: German; right: English 
• Push OK button to save the setting – display indicates "next menu item". Push 
ESC key to leave the service menu – display indicates Operation
Language
english
OK/ESC
Adjustment
105 %
OK/ESC