8    Technical Specification 
Only adept maintenance staff may accomplish work inside 
the equipment! 
8.2 
Terminal Block Pin Assignment  X1, X2 and X3 
The terminal strips are located within the control cabinet. All terminals are labelled in 
accordance with the following table. Only authorised and properly qualified service 
staff as defined in Section 2.4.2 must be permitted to open the control cabinet. 
8.2.1 
Terminal Block X1 Motor A (only for Information) 
 Signal 
internal 
external 
+24V 
Power supply  
Pressure switch Part A 1 
+24V 
Power supply  
Limit switch container A sw 
+24V 
Power supply  
Motor cable red 
+24V 
Power supply  
  
Right rotation 
Q1 
Motor cable blue 
0-10 Volt 
Pot centre green 
Motor cable pink 
Motor A OK 
I3 
Motor cable white 
Overpressure 
I1 
Pressure switch Part A 2 
Container A 
empty 
I5 
Limit switch container A rt 
10 
GND 
Power supply  
Motor cable A sw 
11 
GND 
Power supply  
Pot GND white + shield / Z1 
12 
Left rotation 
Q2 
Motor cable yellow 
13 
Analogue 
GND 
Power supply  
Motor cable purple 
14 
+8Volt 
Stabiliser 7808 
Pot + brown / Z2