Hayward Pools Marine Sanitation System 2100 Benutzerhandbuch

Seite von 7
3
The Spa Aux may also be turned on from the Master Panel by pressing “SPA” followed by “AUX1” within 5 seconds.
BUTTON FUNCTIONS FOR MASTER CONTROL PANEL
& SPA SIDE CONTROL PANEL
UP BUTTON- Used in conjunction with Program
button for many automatic settings, including fill
valve operation (if installed). 1-2 hour time out.
DOWN BUTTON- Displays Ph and/or ORP
and/or PSI with each press (if installed). Used in
conjunction with Program button.
PROGRAM BUTTON- Used when setting
automatic features and water temperatures and
fill features.
FILTER BUTTON- Turns the filter pump on
and off, 4 hour time out.  NOTE:  If the filter
pump is 2-speed: the sequence is low, high,
off. When the filter program is engaged, the
low speed pump will run. When Aux 1 is a
cleaner pump, it will automatically engage the
high-speed filter pump. It will always run in
high speed when calling for heat.
LIGHT BUTTON- Switches the light(s) between
high, medium, and low intensity on 120V
systems only.  Turns light(s) on/off on low
voltage lighting system.  12 hour time out.
AUXILIARY BUTTON - turns the spa auxiliary on and off, 2 hour time out. If blower feature is enabled,
sequence is: Spa Aux, Blower, Spa Aux and Blower, Off.
TEMP BUTTON - controls the set temperature of the spa.
A. Press the temp button once to display the temperature previously set.This display will revert back to the current
air/water temperature. 
B. Pressing the temp button again will cause the temperature setting to increase or decrease depending on what
direction was last chosen. Each press to follow will change the temperature in the same direction.
C. If the opposite direction is desired, release the button and allow display to cycle back to current air/water
temperature. 
D. Press temp button again to display the temperature set. Press temp button again to change temperature setting
in desired direction.
SPA BUTTON - switches the valve between spa and pool, 24 hour time out when in the spa position, turns the
filter pump on in the spa position.
LIGHT BUTTON - switches the light(s) between high, medium, and low intensity on 120V systems
only.  Turns light ON/OFF on low voltage systems. 12 hour time out.
SPA BUTTON- Switches the valve between spa
and pool, 24 hour time out when in Spa position,
turns the filter pump on in the spa position. Filter
pump will turn off when valves are turning.
HEATER BUTTON- Enables/Disables Heat 
Seek feature. 
NOTE:  Heater Cool Down Feature 
The pump will stay on after the heater turns off
for a 10-minute cool down period. This safety
feature also extends the life of the heater.
NOTE:  Heat Seek Feature (temp polling) -
Once the set temp has been realized, the heater
will go into sleep mode.  Every hour the pump
will turn on for 5 minutes to register the
temperature. If it is 2 degrees below the set
temp, the heater will enable.  If the temp has not
dropped below 2 degrees of the set temp, the
system will go back into sleep mode.
MASTER CONTROL PANEL BASIC FUNCTION BUTTONS
SPA SIDE CONTROL PANEL BASIC FUNCTION BUTTONS
AUXILIARY 1 -  6A max  
A. Turns the pool feature on and off. Will not 
activate filter pump if dip switch #4 is down.
B. Controls the cleaner pump in conjunction 
with the filter pump if dip switch #4 is in the 
up position. 
C. If dip switch #4 is in the up position and the 
filter pump is running when the Aux 1 button 
is pushed, the cleaner pump comes on 
immediately. 
D. If the filter pump is not running when the 
Aux 1 button is pushed, the cleaner pump 
will delay for 4 minutes before it comes on; 
24 hour time out. 
E. Auxiliary 1 disabled in spa mode if dip switch
#4 is in the up position.
AUXILIARY 2 - 
Turns the feature on and off; 12 hour time out.
AUXILIARY 3 - 
Turns the feature on and off; 24 hour time out.
Filter pump turns on with feature.
(If in Spa Mode - valves switch to Pool Mode)
AUXILIARY 5 - 
Turns auxiliary 5 output on the expander board
on and off.  12 hour time out.
AUXILIARY 4 - 
Optional Pool Light:
A.  Controls the optional pool lighting circuit. 
The 1st press turns on the light. 
B.  The button is pressed again AFTER 5 
SECONDS, the light turns off. 
C.  If the button is pressed again BEFORE 5 
SECONDS, the Aux 4 option will operate. 
D.  The next press stops the Aux 4 option and 
the next turns the light off. 12 hour time out.
On/Off Light Option: