Bosch Appliances Home Security System D7412G Benutzerhandbuch

Seite von 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 52
Bosch Security Systems | 1/04 | 47775E
CF### Key Strokes
Default:
See 
Program Record Sheet
Selection:
Up to 32 characters: 0 to 9, A, B, C,
D, and E
Selection
Key
Faceplate Label
0 to 9
0 to 9
A
[COMMAND]
B
[PREV] (previous)
C
[ESC] (escape)
MENU
D
[NEXT]
E
[ENT] (enter)
YES
The keystrokes simulate any sequence of keystrokes
the user can perform at a command center. You can
program up to 32 keystrokes for each Custom
Function.
0101
0101
0101
D5200 Data Entry:  Use the D5200 [
]
key to move the cursor to the first data
entry line. When you want to enter more
than sixteen keystrokes, the first line of the
data entry line must be filled before you
move on to the second line. If you make
entries on the second line, and the first line
has less than sixteen characters, the
second line clears when you press
[ENTER].
0101
0101
0101
The scope of the command center where
the Function List is accessed can affect
the way the Custom Function operates.
Programming Custom Function Keystrokes
 
First, find the command you want to execute in
the User Interface section of the Program Record
Sheet
.
 
Single digit commands must be programmed
with 9 as the second digit.
Table 24: CF### Custom Function Keystrokes
Command
Keystroke
1 (Master arm area)
A19
2 (Perimeter instant arm)
A29
3 (Perimeter delay arm)
A39
6 (Watch Mode)
A69
7 (Special alert)
A79
8 (Perimeter partial  arm)
A89
9 ( Special alert)
A99
0 (Bypass a point)
A09
 
128 to 143 Enable Custom Function 128
through 143, (Menu Function only): This
function determines if a passcode is required
when attempting to access a Custom Function
from the menu list. 
ENTER PASSCODE
 (or
Enter Passcode + Enter Key
 on the
D1260) displays when this function is passcode
protected.
0101
0101
0101
If a command within the Custom Function
is passcode protected, the command
center displays 
ENTER PASSCODE
 and
waits for the user to enter a valid
passcode before proceeding with the rest
of the Custom Function. If a passcode is
not entered within 10 seconds, the
Custom Function times out and the display
returns to idle text.
0101
0101
0101
Skeds cannot execute Custom Functions
that are passcode protected. D720 LED
command center does not support
Custom Functions that are passcode
protected.
 
Some functions cannot be entered directly
because they are nested inside a higher-level
function. To automatically execute these
functions, you must add the appropriate
keystrokes.
 
For example: In the Change Display
(COMMAND 49) function there are three sub-
functions: Bright Display, Dim Display, and
Date/Time Display.
To turn up the display, enter:
[A][4][9][E]
To dim the display, enter:
[A][4][9][D][E]
To display time and date, enter:
[A][4][9][B][E]