SAFETY INSTRUCTIONS 
READ ALL INSTRUCTIONS CAREFULLY.
1.  The installation of this unit must comply with 
your local building code rulings. Please ob-
serve the clearances to combustibles (fig. 2). 
2.  Do not install this unit in a mobile home or 
trailer (NO EXCEPTIONS).
3.  Always connect this unit to a chimney and vent 
to the outside. Never vent to another room or 
inside a building.
4. 
DO NOT CONNECT
 this unit to an aluminum 
Type B gas vent. This is not safe. 
5. 
CAUTION:  DO  NOT  INSTALL  THE  HEAT  
GRABBER IN A HORIzONTAL POSITION
.
6.  The paint used on your Heat Grabber may give 
off smoke and/or odor during the first fires. 
This may occur during the first dozen fires 
until the paint has cured. This will end and not  
reoccur after paint has cured. Persons with lung 
conditions or owners of susceptible domestic 
pets (such as birds) should take prudent precau-
tions. Open windows and doors as needed to 
clear smoke and odor. 
7.  Be sure that your chimney is safely constructed 
and in good repair. Have the chimney inspected 
by the fire department or a qualified inspec-
tor. Your insurance company may be able to  
recommend a qualified inspector.
8.  Creosote or soot may build up in the chimney 
connector  and  chimney  and  cause a house/
building fire. Inspect this unit, the chimney 
connector, and chimney twice monthly during 
the heating season and clean if necessary (see 
Maintenance & Service Hints, page 5 .)
9.  Do not install the Heat Grabber on a stove, 
heater, or fireplace pipe that has poor draft or 
“smokes.” The Heat Grabber will aggravate 
this  condition.  Correct  the  draft  situation  
BEFORE installing.
10. Do not use a Heat Grabber that has a smaller 
diameter than the flue outlet on your stove, 
heater, or fireplace. 
11. Do not connect duct work to the Heat Grab-
ber. Do not restrict the air movement inside or 
through the Heat Grabber.
12. Do not install on a stove, heater, or fireplace 
with an operating temperature of less than 350 
degrees Fahrenheit.
13. Do not install the Heat Grabber closer than 12” 
to any combustible object or material. Maintain 
all clearance requirements of the heating appli-
ance (see the appliance’s owner’s manual.)
14. Use at least 
three (3) sheet metal screws at each 
connection to secure the Heat Grabber to the 
flue pipe.
15. While  in  operation,  keep  the  soot  remover 
scraper knob pulled out at least 5 inches from 
the front of the unit.
16. Do  not  touch  the  Heat  Grabber  while  it  
and the heating appliance is in operation. The 
surfaces are hot and can cause severe burns. 
Keep  children,  clothing,  and  combustible  
materials away from the unit.
17. Do not allow the power cord to touch any hot 
surfaces. Keep the power cord at least 12” away 
from the flue pipe.
18. Use only with a grounded electrical socket. 
Consult a qualified licensed electrician to pro-
vide a properly grounded socket. Do not modify 
the electrical plug in any way. Dangerous or 
damaging conditions could result. Do not plug 
into an electrical outlet that is not grounded 
or that is operated by a wall mounted on/off 
switch. 
19. The  Heat  Grabber  MUST  be  plugged 
into  an  electrical  outlet  whenever  the 
stove is in use. Failure to do so will likely  
result in damage to the electrical components 
of the Heat Grabber and could result in shock 
or electrical fire.
20. Keep the unit plugged in at all times. Do Not 
operate the stove if the Heat Grabber is inop-
erative. Doing so will damage the electrical 
components.
  NOTE: A PROFESSIONAL, LICENSED HEATING  
AND COOLING CONTRACTOR SHOULD BE  
CONSULTED  IF  YOU  HAvE  qUESTIONS   
REGARDING THE INSTALLATION.
CAUTION: SHOCK HAzARD
• ALwAYS  DISCONNECT  PLUG  FROm  ELEC-
TRICAL  SOURCE  BEFORE  ADjUSTING  OR 
ATTEmPTING REPAIRS.
 •  ALwAYS  DISCONNECT  PLUG  BY  GRASP-
ING  PLUG  BODY  –  DO 
NOT PULL ON CORD TO  
DISCONNECT  FROm 
wALL OUTLET.
       
•  USE ONLY wITH PROP-
ERLY GROUNDED OUT-
LET.  DO  NOT  ALTER 
PLUG.
..
Figure 1