Vogelzang International Electric Heater HG-8 Benutzerhandbuch

Seite von 8
VGZ-017 / 0707.0
HG-6 & HG-8 Heat Grabber /
Page 3
Refer to diagram and parts lists at back of this 
manual.
1.  Check the Owner’s Manual for your stove and 
do not reduce any minimum clearances which 
may be listed there. Use only Type A (all-fuel) 
or lined masonry chimneys to connect to your 
stove.  Check  your  local  and  state  building 
codes for proper and safe installation.
2.  If you have determined your chimney to have 
an inadequate draft, overcome that deficiency 
before  installing  your  Heat  Grabber. Your 
chimney should be capable of developing at 
least 0.06 w.c. (measured in water column) 
draft before installing a Heat Grabber. After 
installation, the chimney should develop at 
least 0.045 w.c. as measured below the Heat 
Grabber. All stove pipe above or below your 
Heat Grabber must be 24-gauge or heavier to 
provide adequate support. Any horizontal run 
of pipe must pitch upward toward the chimney 
at least 1/4” per foot of horizontal run. All stove 
pipe and/or elbow joints must be secured by at 
least three (3) sheet-metal screws.
3.  Any elbow installed below your Heat Grabber 
should be of the non-adjustable type.
4.  If your stove requires a hand damper (wood 
and  coal  stoves),  install  BELOW  the  Heat 
Grabber.
5.  NOTE: The power cord must not contact any 
part of the stove, chimney connector(s) or the 
Heat Grabber components. Secure the power 
INSTAllATION INSTRUCTIONS
cord to keep it away from hot surfaces or their 
proximity.
6.  The Heat Grabber pipe size must be the same 
or larger diameter than the flue outlet of the 
heating appliance.
7.  All  electric  supply  cord  connections  shall  
comply with the requirements of local authori-
ties having jurisdiction over such matters.
8.  Overfiring  this  unit  is  not  recommended.  
Refer  to  your  heating  appliance  owner’s 
manual regarding overfiring.
9.  The Heat Grabber must be installed in your 
flue pipe vertically. It may be installed with 
the crimped end either up or down, according 
to your installation needs.
10. The Heat Grabber should be installed as close 
to the flue outlet as possible, but no closer than 
15” from the top or back as shown in figure 
2.
11. Do Not install the Heat Grabber closer than 
18” from any combustible material.
12. Use at least three (3) sheet metal screws at 
each connection to secure the Heat Grabber to 
the flue pipe.
13. Keep the power cord at least 12” away from 
the flue pipe.
NOTICE:
 In case of a power outage, your stove 
may be kept in use with low heat fires provided you 
remove the rear panel of the Heat Grabber (fan and 
electrical components).
Figure 2