Vanguard Managed Solutions Vanguard 7300 Series Benutzerhandbuch

Seite von 227
Operating Your Vanguard 7300 
4-21
Vanguard 7300 Port Configuration
Configuring the 
Local Subscriber 
Address 
The Local Subscriber Address parameter is accessed using the Voice Port Record 
Options. To configure your Local Subscriber Address, select the Local Subscriber 
Address parameter, and then enter the phone number you wish to register. That value 
is registered with the gatekeeper as an E.164 address.
This table shows the range, default, and description of the Local Subscriber Address 
parameter:
Changing the E.164 
addresses
If you change an E.164 address, you must force the registration with the gatekeeper. 
Use the steps in this table to re-register a new E.164 address:
Figure 4-12. H.323 Node Parameter Menu
Range:
0 to 21 alphanumeric characters <space> blanks the field
Default:
(blank)
Description:
Specifies the Local Subscriber Address when the remote port is an 
ISDN or Q.SIG port.
The Local Subscriber Address must be specified when Call 
Control parameter is set to Switched and the Use Local Subscriber 
Address parameter is Enabled. Under this configuration, this Local 
Subscriber Address is used to search the Voice Switch Table.
Step
Action
1
Reconfigure the IP address of the gatekeeper in the Vanguard gateway 
using the H.323 Node Parameters. Figure 4-12 illustrates the H.323 Node 
Parameter record.
2
Boot the H.323 Node Parameters to unregister the gateway.
3
Configure the gatekeeper’s IP address back to the original address.
4
Boot the H.323 Node Parameters to reregister with the gatekeeper.
--Gatekeeper IP Address
--Gatekeeper Port Number
--Gateway Time to Live Timer
--Prefix
Node:
Address:
Date:Time:
Menu: Configure
Path: 
H.323 Node Parameters