Vaillant VRT 392f Bedienungsanleitung

Seite von 36
13
Operating manual VRT 392f 0020044239_01
08:00
12:00
15 °
20 °
25 °
R
oom t
emper
atur
e
Time
Period
08:00
12:00
15 °
20 °
25 °
Time
Period
2
3
4
1
Set back
temperature
R
oom t
emper
atur
e
Fig. 4.11   Duration of validity of target value changes 
(here: Target room temperature)
The upper diagram in Fig. 4.11 shows a programmed time 
window (see Section 4.7.1) and corresponding room 
target temperature (21 °C).
In the lower diagram, at (1) the value of the room 
temperature is changed (20 °C). The control system 
uses this  value until the start of the time window.
From here (2) the control system uses the room 
temperature of the time window (21 °C).
At (3) the value of the room temperature is changed  
(17 °C).
The control system uses this value up to the end of the 
time window (4).
Once the time window has elapsed, the system is 
controlled with reference to the set-back temperature 
(15 °C). 
h
 Note 
The characteristic described also applies to the 
same extent for the target hot water.
4.5 
Operation level for the operator, 
operation level for the expert technician
The VRT 392f is equipped with two operation levels. 
Each level contains several screens in which the various 
parameters can be displayed, adjusted or changed. 
–  Operation level for the operator 
Used to display and set/change the basic parameters. 
The setting/changing of parameters can be carried out 
by the user without any special previous knowledge 
and during normal operation.
–  Operation level for the expert technician 
Used exclusively by the expert technician to display 
and set/change specific parameters.
4.6 
Screens at the operation level for the 
operator
The screens at the operation level for the operator are 
arranged according to the sequence shown in Table 4.4 
below.
This table shows you which parameters you can adjust 
and change.
Examples of this are given in Section 4.7 and in the 
following sections.
This is the way you get from the simplified basic display 
to the first display screen "basic data" of the operator 
level:
 
Click one or both dials.
You get to the basic display.
 
Turn the left-hand dial by one or two  points in the 
clockwise direction.
Basic data
 1
Date
21. 06. 06
Day
We
Time
12 : 00 o'clock
Summer/Winter changeover
 
Auto
> select day
Fig. 4.12   Screen "basic data"  
(example: selecting the day of the week)
By turning the left-hand dial further you will scroll from 
one screen to the next.
If accessory components are installed and are controlled 
via the VRT 392f, additional screens apart from those 
listed in Table 4.4 can be displayed, e.g.   3 or   6.
 Operation 4