Advanced Configuration
AP-4000 Series User Guide
Alarms
85
Alarms
The Alarms tab has the following sub-tabs:
Groups
Alarm groups can be enabled or disabled via the Web interface. Place a check mark in the box provided to enable a 
specific group. Remove the check mark from the box to disable the alarms. Alarm severity levels are as follows:
• Critical alarms will often result in severe disruption in network activity or an automatic reboot of the AP.
• Major alarms are usually activated due to a breach in the security of the system. Clients cannot be authenticated 
because an attempt at unauthorized access into the AP has been detected.
• Informational alarms provide the network administrator with some general information about the activities the AP is 
performing.
Configuration Trap Group
Trap Name
Description
Severity Level
oriTrapDNSIPNotConfigured
DNS IP address not configured
Major
oriTrapRADIUSAuthenticationNotConfigured
RADIUS Authentication not configured
Major
oriTrapRADIUSAccountingNotConfigured
RADIUS Accounting not configured
Major
oriTrapDuplicateIPAddressEncountered
Another network device with the same IP address 
exists
Major
oriTrapDHCPRelayServerTableNotConfigured The 
DHCP relay agent server table is empty or 
not configured
Major
oriTrapVLANIDInvalidConfiguration
A VLAN ID configuration is invalid
Major
oriTrapAutoConfigFailure
Auto configuration failed
Minor
oriTrapBatchExecFailure 
The CLI Batch execution fails for the following 
reasons:
• Illegal Command is parsed in the CLI Batch 
file
• Execution error is encountered while 
executing CLI Batch file
• Bigger file size than 100 Kbytes
Minor
oriTrapBatchFileExecStart 
The CLI Batch execution begins after file is 
uploaded
Minor
oriTrapBatchFileExecEnd 
The execution of CLI Batch file ends.
Minor