Protec PROTEK II SN Benutzerhandbuch

Seite von 10
5
4.0  OPERATING PROCEDURE
4.1  HANDLE PROBE CAREFULLY
4.2  Taking Measurements
1.  Press the 
ON
 key to turn on the power. The LCD will 
     momentarily flash SABERN and all of the indicators
     will be illuminated. The display will then show 
     “-- -- --” along with the selected units of measure
     indicator:
a.   mils/thou
: English
b.   um (microns) : Metric
     To change units of measure press the
     key. Refer 
     to  section 6.0 for additional details.
2.  Hold the probe by the outer plastic shell and gently 
     press the tip against the surface to be measured. Use 
     enough pressure to cause the outer shell to contact the 
     measurement surface.
     A thickness reading in mils or microns will be 
  
     displayed.
4.3  Notes on Measurements
1.  The gauge will automatically turn the power off after 
     90 seconds on non-use. To manually turn off  the 
     power press  the
 ON
 key.
2.  The CTI series are continuous reading type gauges 
     which will provide readings as long as the probe is in 
     contact with the surface. When the probe is removed, 
     the minimum reading that was measured will be    
     recalled to the display and will be retained until a new
     measurement is taken.