6.0  CHANGING UNITS OF MEASURE
To change the units of measure from mils to microns, and
vice versa, press the    0N       +     
key.
Each time this combination of keys are pressed the units
will change from one to the other. The unit of measure
indicator, located in the upper right corner of the display,
will also change.
7.0 CAM MODE
      (COUNTED AVERAGE MEASUREMENT)
The Counted Average Measurement mode is a special 
feature which permits the user to take a series of 
consecutive measurements ( from 2  to  99 ) which are 
then averaged.
Enter  CAM  Mode
1- Press the 
 key .
    The display will show “CAM  MODE
2- Press the 
  key. The display will show “CAM  2
3. Press            or  
key to increase or decrease the
    number of measurements. Once the desired number of 
    measurements is shown on the display (for example: 
    “CAM  7”), press the 
ON
 key. The display will show 
    “-- -- --” and the CAM indicator will be displayed.
NOW, THE GAUGE IS READY TO MEASURE  
7
  
CONSECUTIVE MEASUREMENTS AND DISPLAY 
THE AVERAGE OF THE  
7
  READINGS.