About the Trigger Signals
Trigger signals (GPI1 - 16), which are used for recording 
control and Color Camera control, consist of edge and level 
signals.
   Edge signals
High-edge, low-edge and both-edge of an edge signal can 
be specified. Control specified by Action starts when a 
change in an edge of the specified signal is detected.
High-edge
Both-edge
Low-edge
(Time)
High
Low
For example, when a high-edge of “AUTOZOOM” 
is specified
Start of AUTOZOOM
(Time)
High
Low
   Level signals
The high-level and low-level of a level signal can be 
specified and control specified by Action (recording control) 
occurs when a change is detected in the specified signal.
When high-level is specified:
A change in the signal from low to high starts recording 
and a change from high to low stops it.
Recording starts
Recording
stops
(Time)
High
Low
When low-level is specified:
A change in the signal from high to low starts recording 
and a change from low to high stops it.
Recording starts
Recording stops
(Time)
High