9.2
Programming Standalone (SA) Mode
9.2.1
EDMA3 Programming
9.2.1.1
Input Configuration Parameters Transfer
9.2.1.2
Systematics and Parities Transfer
Programming
www.ti.com
highlights the required EDMA3 resources to perform a standalone (SA) mode decoding. Each
set of EDMA3 parameters uses the EDMA3 linking capabilities.
details the EDMA3 transfers
programming and
details the input parameters programming. Any notification mechanism to
flag that a user-channel has just been decoded is left to you. Suggested implementation is to use the
EDMA3 interrupt generation capabilities [see the TMS320C6457 DSP Enhanced Direct Memory Access
(EDMA3) Controller Reference Guide 
(
)] and program the EDMA3 to generate an interrupt after
the user-channel's last TCPREVT synchronized EDMA3 transfer has completed.
This EDMA3 transfer to the input configuration parameters is a 16-word TCPXEVT frame synchronized
transfer. The parameters should be set as:
OPTIONS
ITCCEN = 0 (Intermediate transfer complete chaining is disabled)
TCCEN = 0 (Transfer complete chaining is disabled)
ITCINTEN = 0 (Intermediate transfer complete interrupt is disabled)
TCINTEN = 0 (Transfer complete interrupt is disabled)
TCC = 1 to 63 (Transfer Complete Code)
TCCMODE = 0 (Normal Completion)
FWID = Don't care
STAT = 0 (Entry is updated as normal)
SYNCDIM = 0 (A-Sync. Each event triggers the transfer of ACNT elements.)
DAM = 0 (Dst addressing within an array increments. Dst is not a FIFO.)
SAM = 0 (Src addressing within an array increments. Source is not a FIFO.)
SOURCE ADDRESS: User input configuration parameters start address (must be double-word
aligned)
ACNT = 64 (No of bytes in an array - 16 32 bit Input Configurations to be transferred)
BCNT = 1 (No of arrays of length ACNT)
DESTINATION ADDRESS: TCPIC0 (5000 0000h)
SRCBIDX = 0 (Source 2nd Dimension Index)
DSTBIDX = 0 (Destination 2nd Dimension Index)
SRCCIDX = 0 (Source 3rd Dimension Index)
DSTCIDX = 0 (Destination 3rd Dimension Index)
CCNT = 1 (No of frames in a block)
BCNTRLD: Don't care
LINK ADDRESS: Address in the EDMA3 PaRAM of the EDMA3 parameters associated with the
systematics and parities
Upon completion, this EDMA3 transfer is linked to the EDMA3 for systematics and parities transfer
parameters.
This EDMA3 transfer to the systematics and parities memory is a TCPXEVT frame-synchronized transfer.
The parameters should be set as:
OPTIONS:
ITCCEN = 0 (Intermediate transfer complete chaining is disabled)
TCCEN = 0 (Transfer complete chaining is disabled)
ITCINTEN = 0 (Intermediate transfer complete interrupt is disabled)
66
TMS320C6457 Turbo-Decoder Coprocessor 2
SPRUGK1 – March 2009