 Circuit card installation
9
If there is an enable/disable switch, set it to Enb.
Note: Do not enable the switch on an NT8D04 Superloop Network card 
or QPC414 Network card until network loop cables are installed.
10 If you are adding a voice, conference, or tone and digit loop, press the 
manual initialize (Man Int) button on the NT5D03 or the NT5D10 Call 
Processor if the card is associated with the active Call Processor:
Note: An initialization causes a momentary interruption in call 
processing.
11 If you are installing the card in a working system, refer to the work order 
and the Software Input/Output: Administration (553-3001-311) to add the 
required office data to the system memory.
12 Go to the appropriate test procedure in “Acceptance tests” on